Absorbance
Template:Short description Template:About Template:Redirect
Template:Technical In spectroscopy, absorbance (abbreviated as A)<ref>Template:Cite encyclopedia</ref> is a logarithmic value which describes the portion of a beam of light which does not pass through a sample. While name refers to the absorption of light, other interactions of light with a sample (reflection, scattering) may also contribute attenuation of the beam passing through the sample. The term "internal absorbance" is sometimes used to describe beam attenuation caused by absorption, while "attenuance" or "experimental absorbance" can be used to emphasize that beam attenuation can be caused by other phenomena.<ref name=":1" />
History and uses of the term absorbance
Beer-Lambert law
The roots of the term absorbance are in the Beer–Lambert law (or Beer's law). As light moves through a medium, it will become dimmer as it is being "extinguished". Pierre Bouguer recognized that this extinction (now often called attenuation) was not linear with distance traveled through the medium, but related by what we now refer to as an exponential function.
If <math>I_0</math> is the intensity of the light at the beginning of the travel and <math>I_d</math> is the intensity of the light detected after travel of a distance Template:Nowrap the fraction transmitted, Template:Nowrap is given by
<math display="block">T=\frac {I_d}{I_0} = \exp(-\mu d)\,,</math>
where <math>\mu</math> is called an attenuation constant (a term used in various fields where a signal is transmitted though a medium) or coefficient. The amount of light transmitted is falling off exponentially with distance. Taking the natural logarithm in the above equation, we get
<math display="block">-\ln(T) = \ln \frac {I_0}{I_d} = \mu d\,.</math>
For scattering media, the constant is often divided into two parts,<ref>Template:Cite book</ref> Template:Nowrap separating it into a scattering coefficient <math>\mu _s</math> and an absorption coefficient Template:Nowrap obtaining
<math display="block">-\ln(T) = \ln \frac {I_0}{I_s} = (\mu_s + \mu_a) d\,.</math>
If a size of a detector is very small compared to the distance traveled by the light, any light that is scattered by a particle, either in the forward or backward direction, will not strike the detector. (Bouguer was studying astronomical phenomena, so this condition was met.) In such case, a plot of <math>-\ln(T)</math> as a function of wavelength will yield a superposition of the effects of absorption and scatter. Because the absorption portion is more distinct and tends to ride on a background of the scatter portion, it is often used to identify and quantify the absorbing species. Consequently, this is often referred to as absorption spectroscopy, and the plotted quantity is called "absorbance", symbolized as Template:Nowrap Some disciplines by convention use decadic (base 10) absorbance rather than Napierian (natural) absorbance, resulting in: <math>\Alpha_{10} = \mu_{10}d </math> (with the subscript 10 usually not shown).
Absorbance for non-scattering samples
Within a homogeneous medium such as a solution, there is no scattering. For this case, researched extensively by August Beer, the concentration of the absorbing species follows the same linear contribution to absorbance as the path-length. Additionally, the contributions of individual absorbing species are additive. This is a very favorable situation, and made absorbance an absorption metric far preferable to absorption fraction (absorptance). This is the case for which the term "absorbance" was first used.
A common expression of the Beer's law relates the attenuation of light in a material as: Template:Nowrap where <math>\Alpha </math> is the absorbance; <math>\varepsilon </math> is the molar attenuation coefficient or absorptivity of the attenuating species; <math>\ell </math> is the optical path length; and <math>c </math> is the concentration of the attenuating species.
Absorbance for scattering samples
For samples which scatter light, absorbance is defined as "the negative logarithm of one minus absorptance (absorption fraction: <math>\alpha</math>) as measured on a uniform sample".<ref name=":0">Template:GoldBookRef</ref> For decadic absorbance,<ref name=":1">Template:Cite book</ref> this may be symbolized as Template:Nowrap If a sample both transmits and remits light, and is not luminescent, the fraction of light absorbed Template:Nowrap remitted Template:Nowrap and transmitted Template:Nowrap add to 1: Template:Nowrap Note that Template:Nowrap and the formula may be written as Template:Nowrap For a sample which does not scatter, Template:Nowrap and Template:Nowrap yielding the formula for absorbance of a material discussed below.
Even though this absorbance function is very useful with scattering samples, the function does not have the same desirable characteristics as it does for non-scattering samples. There is, however, a property called absorbing power which may be estimated for these samples. The absorbing power of a single unit thickness of material making up a scattering sample is the same as the absorbance of the same thickness of the material in the absence of scatter.<ref>Template:Cite book</ref>
Optics
In optics, absorbance or decadic absorbance is the common logarithm of the ratio of incident to Template:Em radiant power through a material, and spectral absorbance or spectral decadic absorbance is the common logarithm of the ratio of incident to Template:Em spectral radiant power through a material. Absorbance is dimensionless, and in particular is not a length, though it is a monotonically increasing function of path length, and approaches zero as the path length approaches zero.
Mathematical definitions
Absorbance of a material
The absorbance of a material, denoted Template:Mvar, is given by<ref name="GoldBook">Template:GoldBookRef</ref>
<math display="block">A = \log_{10} \frac{\Phi_\text{e}^\text{i}}{\Phi_\text{e}^\text{t}} = -\log_{10} T,</math>
where
- <math display="inline">\Phi_\text{e}^\text{t}</math> is the radiant flux Template:Em by that material,
- <math display="inline">\Phi_\text{e}^\text{i}</math> is the radiant flux Template:Em by that material, and
- <math display="inline">T = \Phi_\text{e}^\text{t}/\Phi_\text{e}^\text{i}</math> is the transmittance of that material.
Absorbance is a dimensionless quantity. Nevertheless, the absorbance unit or AU is commonly used in ultraviolet–visible spectroscopy and its high-performance liquid chromatography applications, often in derived units such as the milli-absorbance unit (mAU) or milli-absorbance unit-minutes (mAU×min), a unit of absorbance integrated over time.<ref>Template:Cite web</ref>
Absorbance is related to optical depth by
<math display="block">A = \frac{\tau}{\ln 10} = \tau \log_{10} e \,,</math>
where Template:Mvar is the optical depth.
Spectral absorbance
Spectral absorbance in frequency and spectral absorbance in wavelength of a material, denoted Template:Math and Template:Math respectively, are given by<ref name=GoldBook />
<math display="block">\begin{align} A_\nu &= \log_{10} \frac{\Phi_{\text{e},\nu}^\text{i}}{\Phi_{\text{e},\nu}^\text{t}} = -\log_{10} T_\nu\,, \\ A_\lambda &= \log_{10} \frac{\Phi_{\text{e},\lambda}^\text{i}}{\Phi_{\text{e},\lambda}^\text{t}} = -\log_{10} T_\lambda\,, \end{align}</math>
where
- <math display="inline">\Phi_{\mathrm{e},\nu}^t</math> is the spectral radiant flux in frequency Template:Em by that material;
- <math display="inline">\Phi_{\mathrm{e},\nu}^i</math> is the spectral radiant flux in frequency Template:Em by that material;
- <math display="inline">T_\nu</math> is the spectral transmittance in frequency of that material;
- <math display="inline">\Phi_{\mathrm{e},\lambda}^t</math> is the spectral radiant flux in wavelength Template:Em by that material;
- <math display="inline">\Phi_{\mathrm{e},\lambda}^i</math> is the spectral radiant flux in wavelength Template:Em by that material; and
- <math display="inline">T_\lambda</math> is the spectral transmittance in wavelength of that material.
Spectral absorbance is related to spectral optical depth by
<math display="block">\begin{align} A_\nu &= \frac{\tau_\nu}{\ln 10} = \tau_\nu \log_{10} e \,, \\ A_\lambda &= \frac{\tau_\lambda}{\ln 10} = \tau_\lambda \log_{10} e \,, \end{align}</math>
where
- Template:Mvar is the spectral optical depth in frequency, and
- Template:Mvar is the spectral optical depth in wavelength.
Although absorbance is properly unitless, it is sometimes reported in "absorbance units", or AU. Many people, including scientific researchers, wrongly state the results from absorbance measurement experiments in terms of these made-up units.<ref>Template:Cite journal</ref>
Relationship with attenuation
Attenuance
Absorbance is a number that measures the attenuation of the transmitted radiant power in a material. Attenuation can be caused by the physical process of "absorption", but also reflection, scattering, and other physical processes. Absorbance of a material is approximately equal to its attenuanceTemplate:Clarify when both the absorbance is much less than 1 and the emittance of that material (not to be confused with radiant exitance or emissivity) is much less than the absorbance. Indeed,
<math display="block">\Phi_\mathrm{e}^\mathrm{t} + \Phi_\mathrm{e}^\mathrm{att} = \Phi_\mathrm{e}^\mathrm{i} + \Phi_\mathrm{e}^\mathrm{e}\,,</math>
where
- <math display="inline">\Phi_\mathrm{e}^\mathrm{t}</math> is the radiant power transmitted by that material,
- <math display="inline">\Phi_\mathrm{e}^\mathrm{att}</math> is the radiant power attenuated by that material,
- <math display="inline">\Phi_\mathrm{e}^\mathrm{i}</math> is the radiant power received by that material, and
- <math display="inline">\Phi_\mathrm{e}^\mathrm{e}</math> is the radiant power emitted by that material.
This is equivalent to
<math display="block">T + \mathrm{ATT} = 1 + E\,,</math>
where
- <math display="inline">T = \Phi_\mathrm{e}^\mathrm{t} / \Phi_\mathrm{e}^\mathrm{i}</math> is the transmittance of that material,
- <math display="inline">\mathrm{ATT} = \Phi_\mathrm{e}^\mathrm{att} / \Phi_\mathrm{e}^\mathrm{i}</math> is the Template:Em of that material,
- <math display="inline">E = \Phi_\mathrm{e}^\mathrm{e} / \Phi_\mathrm{e}^\mathrm{i}</math> is the emittance of that material.
According to the Beer's law, Template:Math, so
- <math>\mathrm{ATT} = 1 - 10^{-A} + E \approx A \ln 10 + E, \quad \text{if}\ A \ll 1,</math>
and finally
- <math>\mathrm{ATT} \approx A \ln 10, \quad \text{if}\ E \ll A.</math>
Attenuation coefficient
Absorbance of a material is also related to its decadic attenuation coefficient by
<math display="block">A = \int_0^l a(z)\, \mathrm{d}z\,,</math>
where
- Template:Mvar is the thickness of that material through which the light travels, and
- Template:Math is the decadic attenuation coefficient of that material at Template:Mvar.
If a(z) is uniform along the path, the attenuation is said to be a linear attenuation, and the relation becomes <math display="block">A = al.</math>
Sometimes the relation is given using the molar attenuation coefficient of the material, that is its attenuation coefficient divided by its molar concentration:
<math display="block">A = \int_0^l \varepsilon c(z)\, \mathrm{d}z\,,</math>
where
- Template:Mvar is the molar attenuation coefficient of that material, and
- Template:Math is the molar concentration of that material at Template:Mvar.
If Template:Math is uniform along the path, the relation becomes
<math display="block">A = \varepsilon cl\,.</math>
The use of the term "molar absorptivity" for molar attenuation coefficient is discouraged.<ref name=GoldBook />
Use in Analytical Chemistry
Absorbance is a widely used measurement in quantitative absorption spectroscopy. While the attenuation of a light beam can be also be described by transmittance (the ratio of transmitted incident light), the logarithmic formulation of absorbance is convenient for sample quantification: under conditions where the Beer's law is valid, absorbance will be linearly proportional to sample thickness and the concentration of the absorptive species.<ref name=":2">Template:Cite book</ref>
For quantitative purposes, absorbance is often measured on a sample solution held in a cuvette, where the solution is sufficiently dilute that the linear relationship of the Beer's law holds. The cuvette provides a known and consistent path length for the light beam passing through the sample.<ref name=":2" /> Measuring first the absorbance of the cuvette and a "blank" solution containing no analyte, differences in absorbance between samples can be used to quantity the analyte. Spectrometers generally measure absorbance separately for a range of wavelength: this data is then plotted as absorbance vs. wavelength.<ref>Template:Cite web</ref>
Shade number
Some filters, notably welding glass, are rated by shade number (SN), which is 7/3 times the absorbance plus one:<ref>Template:Cite web</ref>
<math display="block">\begin{align} \mathrm{SN} &= \frac{7}{3} A + 1 \\
&= \frac{7}{3}(-\log_{10} T) + 1\,.
\end{align}</math>
For example, if the filter has 0.1% transmittance (0.001 transmittance, which is 3 absorbance units), its shade number would be 8.
See also
- Absorptance
- Tunable Diode Laser Absorption Spectroscopy (TDLAS)
- Densitometry
- Neutral density filter
- Mathematical descriptions of opacity
References